Customization: | Available |
---|---|
Continuously Charge/Discharge Current: | 150A |
Balance Function: | Passive Balance |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Communication | CANBUS | Continuously Charge/Discharge Current | 50A |
---|---|---|---|
Standard Working Voltage | 51.2V | Balance Function | Passive Balance |
Continuously Discharge Current | 50A | Size | 300mm*100mm*16mm |
Application | NCM/Lifepo4 Battery Pack | Battery Capacity | 5-500Ah |
Series Number | 16S | OEM/ODM | Acceptable |
Function | Monitoring, Thermal Management, Computation, Communication, Protection, Pre-charge, Optimization |
Battery type and serial number | LFP(16S) | NCM(14S) | |||||||
Continuously charging/discharging current | 50A | 100A | 150A | 200A | 50A | 100A | 150A | 200A | |
Communication protocol | CANBUS(defult) RS485(Please contact Sale man) | ||||||||
Custom function | Heating function,External switch,RS485 protocol | ||||||||
Discharge Output Impedance | <2mΩ | ||||||||
Working Temperture | -20ºC-70ºC | ||||||||
compensating impedance | 10mΩ | ||||||||
Pre-charging | 0-3000ms | ||||||||
Current limiting(charging) | 10A | ||||||||
Current Balance | Passive balance | 150mA(Max) | |||||||
Power consumption | Working mode power consumption | <40mA | |||||||
Sleeping mode power consumption | 0uA | ||||||||
Capacity protection | Nominal capacity | 5-500Ah | |||||||
Remaining capacity protection | 5% | ||||||||
Short Circuit protection | Short circuit protection lock | Continuously short in the output circuit | |||||||
Short circuit protection lock times | 5 times | ||||||||
Short circuit protection lock release | Connected with charger | ||||||||
Individual cell voltage protection | Over voltage protection | 3650mV | 4200mV | ||||||
Under voltage protection | 2700mV | 2900mV | |||||||
Voltage protection | Over voltage protection | 57.6V | 58V | ||||||
Under voltage protection | 41.6V | 40.6V | |||||||
Current protection | Over current protection | 60A | 110A | 160A | 210A | 60A | 110A | 160A | 210A |
Over current protection | 30mS | ||||||||
Heating function | Start | 0ºC | |||||||
Stop | 10ºC |