Basic Info.
Product Description
Seplos solar lithium battery module CANBUS/RS485 24/48v 8S-16S 50A/100A/150A/200A lithium battery protection board Cell monitoring systemModel Number | 24V/48V 50/100/150/200A lifepo4 bms |
Product type | BMS Pcba |
size | 300mm*100mm*20mm |
Type | bms pcba |
Copper Thickness | 1 oz |
Application | NCM/Lifepo4 battery pack |
Comuunication | CANBUS or RS485 |
Custom function 2 | Added enable/disable BMS function |
Packaging & delivery
Selling Units:Single item
Single package size: 42.5X13X6 cm
Single gross weight:1.000 kg
Package Type:We wrap the product in shock-proof bubble wrap and place it in custom cowhide cartons filled with specially-shaped pearl cotton and hold it in place
Picture Example:
Lead time:Quantity(pieces) | 1 - 5 | >5 |
Lead time (days) | 15 | To be negotiated |
FAQ
1.
Q: Can the 485 version and CAN version of the V14 BMS change the baud rate of the BMS by refreshing the program?
A: NO, they are different version of the chip.
2.
Q: Is it an equalizing function, active or passive and what is the equalizing current?
A:It's a passive equalizing function with 150mA current.
3.
Q: What is the connection mode of communication when BMS communicates with inverter or 485 communication and CAN communication?
A: External communication means that BMS is connected to CANBUS interface when communicating with inverter (RS485 interface is used for communication with Voltonic inverter)
4.
Q: The BMS cannot work and indicator does not light up.
A: May be caused by D4 diode damage.
5.
Q: Which BMS model suitable for ternary lithium battery?
A:The ternary lithium battery can support up to 14S version of the BMS. The firmware version of the ternary lithium battery BMS is different from the lithium iron phosphate BMS and cannot be used universally.
6.
Q: SMA inverter will report fault when BMS is fully charged.
A: The fault can be solved by refreshing the firmware program (version 2.8). The V16 BMS does not have this fault.
7.
Q: Voltronic inverter and its licensed inverter only have 485 communication version of BMS or new version of BMS (V16 version). How to use the inverter?
A: The Voltonic inverter uses RS485 interface for communication. DIP dialing is different from other versions of BMS. Connect and dial 1on to the host, 2on to the first slave, and 3on to the second slave. You can ask me to send relevant documents.
8.
Q: How is BMS function of SOC calculating and cycle life counting work?
A: First, modify the rated capacity of the battery, then complete a full charge and discharge process,the actual battery capacity will be learned.SOC is calculated by capacity accumulation and voltage calibration.
It has the function of calculating the number of charging and discharging cycles. When the cumulative discharge capacity of the battery pack reaches the set full capacity.At 20% (default), the number of cycles increases one,the set value of battery cycle capacity parameter can be changed through the upper computer.
9.
Q: The issue of battery monitoring software cannot see the master when multiple BMS are in parallel.
A:When multiple BMS are in parallel, the battery monitoring software cannot see the information of the master, only see the information of the slave. If you want to see the information of the master, you need to turn off the DIP of the master and connect it separately or use the LCD screen with Bluetooth function, or use the onboard BMS with Bluetooth function.
10.
Q: Why not message display on LCD screen?
A: 1.The function of LCD did not open.
2.Poor contact of connecting or broken wire of LCD screen.
3.The new version BMS with Bluetooth, but install with an LCD screen without Bluetooth.
11.
Q:limited algorithm of charge current.
A:Unbalanced in current distributed.
1.no charge current if any device is in charging warning of voltage,temperature,and capacity or charging protection.
2.charge current values remain in 10.0A when no device in charging.
3.charge current is base the role if over current is greater than 20.0A then reduce 10.0A,otherwise,remain in 10.0A when single device is charging.
4.charge current is base the role of over current value multiply by device's quantity then divide by two if more than two device is charging.
5.charge current will be cleared and set the chargeable value to 0A when any single cell voltage more than +30mV compare to over voltage protection value with battery pack in parallel.
12.
Q:what if customer want to purchase BMS but the inverter in use is not in compatible list.
A:Customer need to provide the communication protocol of their inverter.
13.
Q:Battery monitoring software not working or load protocol failure.
A:1.Download new program.2.set the correct format language(as below)
14.
Q:The functions of heating and heating pad choosing.
A:BMS with heating function need to customized because the heating pad size is not specific,customer need to purchased by themself and current can not over 4A.
15.
Q:The specification of 12V BMS in series or in parallel.
A:In series or in parallel is available but only individually,4 BMS is limited in series but no limit in parallel.
16.
Q:About firmware program upgrade.
A:Not allow to upgrade the Firmware program without permission,after sales service is not available if its cause any damage.
17.
Q:The temperature shows at -50ºC
A:NTC temperature sensor damaged or welding disengaged.
18.
Q:The conditions to use one key to power on/off.
A:Master BMS can control slave one to power on or off when battery working in parallel.it could not be one key to power on/off if master address is not dial(the new version BMS can be dial automatically) and all BMS is not in standby mode(because current of the battery will flow each other if there is not in standby mode when in parallel).
19.
Q:Is it the BMS can change to another model to use by load the parameter?
A:NO(such as 13S and 14S,15S and 16S can be changed by load the parameter,but this will not recommended because it could be lead to malfunction)
20.
Q:Running normal but there is busbar over voltage warming.
A:Please check if battery circuit connection is correct.
21.
Q:Is there any other way can know the status of BMS?
A:1.browse on PC software.2.check the message on LCD screen.3.check the status of LED in BMS(as description of manual)
Address:
Building 1, No. 147, Qingfeng Road, Qingxi Town, Guangdong Province, Dongguan, Guangdong, China
Business Type:
Manufacturer/Factory
Business Range:
Electrical & Electronics, Metallurgy, Mineral & Energy
Management System Certification:
ISO 9001
Company Introduction:
Established in 2020, Seplos Technology Co., Ltd. is a manufacturer specialized in the research, development and production of lithium battery for energy storage Solutions. We are located in Dongguan, with immense industrial zone advantage. All of our products comply with international quality standards and are greatly appreciated in a variety of different markets throughout the world.
Covering an area of 3000 square meters, we now have over 50 employees, including 6 excellent and experienced engineer in research and development, with the principles of ′innovativeness make the progress′, our engineer keep in technology and product upgrade, guarantee our product is high quality and perfect demands for customers. Since its foundation, our annual sales figure that exceeds USD 100 Million and are currently exporting 90% of our production worldwide. Our well-equipped facilities and excellent quality control throughout all stages of production enables us to guarantee total customer satisfaction.
We have received CE, TUV, MSDS, UN38.3 and RoHS certificate. As a result of our high quality products and outstanding customer service, we have gained a global sales network reaching Germany, the United States, Spain, South Africa etc.
If you are interested in any of our products or would like to be a distributor, please do not hesitate to contact us. We are looking forward to forming successful business relationships with new clients around the world in the near future.